About 50 results
Open links in new tab
  1. NC Garage Legal Finish Requirement | The Building Code Forum

    Jan 29, 2024 · The garage is 100% residential- not a business. The first floor has lights & outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added …

  2. S-1 & S-2 Regarding Parking Garage - The Building Code Forum

    Jan 7, 2015 · Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage". Section 311.3 Classifies "Parking garages, open or …

  3. S-1 Motor Vehicle Storage VERSUS S-2 Enclosed Parking Garage

    Jan 12, 2023 · Is the following facility an S-1 Storage or S-2 Parking Garage? 7,000 SF metal building - fully enclosed with garage doors and walk doors for access - for parking church vans (all smaller …

  4. Garage Open Air Calculations - The Building Code Forum

    Dec 18, 2011 · I am designing a garage, and trying to achieve natural ventilation. I think I have achieved the required 20% open, as well as 40% perimeter open as per IBC 2006, but what if your garage is …

  5. Egress through a garage. | The Building Code Forum

    Apr 9, 2015 · A detached garage is not going to require egress in the same manner as a habitable space. How do you egress out of a garage itself?

  6. When is a portal frame not needed for a garage door?

    Feb 28, 2025 · Typically when I draw a garage I just default to the portal frame since they're usually narrow in my area; not much meat on either side of the door. I have one coming up that is, for once, …

  7. Equipment Bollard in a Residential Garage - The Building Code Forum

    Oct 20, 2009 · Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab. We also have two alternates that are wheel …

  8. Exit Access Stair in Open Parking Garage - Exit Discharge

    Nov 9, 2020 · Typically an exit access stair is locate inboard with the exit travel distance continuing beyond the stair to the exit door, but not in this case due to the open parking garage exception.

  9. Branch Circuit to Detached Garage - The Building Code Forum

    Oct 16, 2009 · An electrical service disconnect is located in or on the main structure. One of the panelboard has a 20A GFCI breaker that is labeled "garage." The garage is detached and the circuit …

  10. Garage distance separation from dwelling - Section R309

    Dec 4, 2009 · Re: Garage distance separation from dwelling - Section R309 Uncle Bob, That's how I see it (I just don't believe it). I would not interpret measuring from overhang. Any other comments on …